Hi, my above ground pool pump will run when not attached to the pool and there is no water in it, but when I get it hooked up to the pool and let the hoses and pump fill, it no longer turns on. Shaft seals may blow out if a valve after the pump is turned or briefly closed while the pump is running. Hi Robin, an F5 code? If the motor was submerged, it may not recover. type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. Please advise. If the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re-light. Thank you for the quick response. You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. Hi Jennifer, many Matrix pumps have an on/off switch on the rear bottom of the motor cap end. We have a Hayward Super Pump 260710 that is 1 hp.The pool was working fine when we opened it 1 week ago except after it would run for 15-20 mins the motor would trip the circuit breaker so we had an electrician replace the motor and check the electrical and that was fine; however, we cant get the pump primed. This year, I have replaced all the plumbing from the pump to the filer. So I messed with the wires a little and I got it to turn back on. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. Hi Leah, good question, and I understand. Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. The pump has been fine since installed, we started up he pool about 30 days ago no issues. Hi Kathy, the clicking could be the start switch in the rear of the motor, not fully disengaging. I am getting a CEL code and the heater will not run. I have a 2 speed motor and the high will not start at start up. It is a common problem with Hayward Perflex, the symptoms you describe, and is usually clogged fingers. Though it is a different control, they use the same cell; so if you are getting a temperature reading of 215, you need to replace the cell. Probably not a pump or motor problem (but could be). Before you purchase a new Hayward pool pump, its important to verify that the pump is the right size for your pool piping. 1. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. There should be no elbow after the flow switch. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. Question my Aquaririte is 3 years old. We opened our pool today, ran the pump for about 7 or 8 hours and the plug on the pump was actually melted to the outlet on our timer. Yes, you can briefly test motors, for a few seconds without water, no problem. Our troubleshooting guide will help you get it up and running in no time. For either sand or DE, if you experience high pressure or poor filtration after backwashing or cleaning, try a Pool Filter Cleaner product to deep clean the filter. When I turn the switch on for the pool, the breaker flips immediately. I have a Hayward pro series filter and Hayward pump. Hi Paul, could it be vibration noise? It could also be something loose inside of the tank. Thank you. The filter is clean. Flex pipe used on skimmers can eventually narrow and crimp, leaving a small opening that clogs easily. If your cell looks like 4A, continue to Step 4. Hi. this is the black cylinder in the rear, at 9 oclock. Is there a trick to this? What should I check? My prior one was over 12 years old so Im feeling uncertain. 4. leaky valve or unions in front of pump I took apart the impeller and didnt see anything that could cause a problem. What am I missing? Pump does not overheat or shut off or anything and continues to circulate the water normally, just making a lot of noise, so I have not been running it. The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. 4. clogged pump impeller Should I have it checked or is this normal? men's rhinestone dress shoes. We even tried siphoning with a hose and it dont want to work either. Run motor with impeller alone for brief second, sounds perfectly quite and normal. Any thoughts? Hi Virgil, the time clock may not be set, or if you have a controller, the on/off program may not be setup, so it runs until it is set to turn off but is not set to turn back on again? Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). Most above ground pool pumps are not self-priming, and mot inground pumps are self-priming. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. I have a Hayward pump that will backwash but nothing else. A very thin layer of rust develops between the stator and the rotor inside the motor, and getting a 7/16 open end wrench on the end of the shaft, and working it back and forth, breaks the rust and frees up the shaft to spin. Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. Is there a disconnected wire in the back of the motor? Look at the diagram on the top center of the motor, which may provide some help, if not, call Hayward (908) 355-7995 (U.S.). We would like to show you a description here but the site wont allow us. Put your foot on the motor and apply a little weight, to see if the noise stops. Hi, Hard for me to say if the motor is shot, but it has sure had a rough life! Would Hayward do anything for me? Hayward Pool Pump Troubleshooting - In The Swim Pool Blog We tried opening the pool today when we plugged in the Hayward filter it keeps blowing the circuit breaker. Products, Learn About Upon restart, pump sounds horrible, like pumping rocks. We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. Put it in the line at the pool, and as the pump begins to catch prime, crimp the hose and slowly pull out of the pipe. i have a 4 wire set up, ground, line , low speed,high , just want to make sure i wire correctly, 1- line 1, 2- high speed, 3or4 to low speed? March 2023 Issue - Donovan's Bookshelf Works great minus the vacuum created is so great that getting the lid off of the basket is so great a breaker bar is needed to remove it. Pat. Of course, be sure the pool water level is good, and the skimmer weir door is not stuck, or blocking water flow into a skimmer. When I go to backwash the filter pump shuts down. You can also turn off the pump at the breaker which provides power to the timer. We were cleaning our pool filter one day and went to restart the pump and it didnt. How To Troubleshoot Problems with Your Salt Cell - Royal Swimming Pools Hi, it could be just that, a vibration. The salt cylinder is clean. Step 4: If none of the previous steps solved the problem, replace your flow switch. Next, check continuity from lead to lead. Does the panel just need to dry or did I cause possible damage? Reassemble pump in reverse order from above. When I turn on the pump, it sucks water through but only 2/3 of basket is filled as if a suction leak. If youre reading this blog that means you need help troubleshooting your Hayward Aqua Rite salt system. It can also just be a really dirty filter, or a clogged pump impeller. It could be a problem the other way around, AG pumps cannot lift water vertically, so are not used on inground pools. Ive tried setting up the vacuum with power on and power off and its no different. 1. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. Thats unusual, shouldve fixed it. Pump motors are continuous duty, meaning that they are meant for continuous operation, it wont harm the motor, or cause it to overheat. Any ideas how to address this? ), maybe you can swap Assy B motor, but you say thats noisey, it could need new bearings and shaft seal. it runs put on high speed. It DOES turn on. Inspect the capacitor, at 9 oclock in the rear, for bulges, cracks or brown liquid. I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. Also, using Teflon pool lube on the pump lid oring should help. Is it time for a replacement pump? If not that, it could be a loose wire connection. First time pool owner (obviously dont know what we are doing). On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! 12 ga or 14 ga? I calibrated the unit to 3100 ppm. "headline": "Hayward Pool Pump Troubleshooting",
At a total loss here, any suggestions would be greatly appreciated. 5. (GFI 240V 20amp) Timer 1 comes on at 10:30 at 1450rpms and runs to 3:30. Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). It makes humming sound 1-2 times before starting. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? We just has this pool installed year, and brought the motor inside the house. My pool suppoier said 50lb but the info on the description of the filter on the site where purchased says 100 lbs. stranger things backpack hot topic. The breaker is probably overloaded. easier. Good morning. Trying not to damage impeller. YOu can shim under a piece of rubber, or carpet, or cardboard which wont last long, but anything between the pump and the pad should quiet the pump, and take up space to prevent the vibration. Now I am looking to replace the old filter. If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. I have a Hayward Perflex DE filter brand new last year. Replacement of the gasket inside the valve is the fix. Try adding another inch of water. Ive been told my Hayward Vsp has been shutting itself off for low power issues, even though no power issues are present. If the shaft is free turning, but the pump does not turn on, check power connections. Factory Direct Pricing Whichever brand they go with, we know that our customers are always looking to get the best price. Automatic reset is immediate once the gas valve relay check results are acceptable. it does not turn on even though i get 240 volts.My blower is on a different circuit and works properly with 240 volts. I have a perflex ec50 that is about four years old. I have opened a pool and I have kept pump running 24 hrs due to Alge but few hours later there is no water moving in pool. If it is not a clog, it could be a collapsed skimmer line or drain line, if flex pipe was used underground on these lines. Sean, Hi Sean, no worries. Is this a 2-speed pump, or variable speed pump? We are a registered 501(c)3 non-profit that is funded by user donations. Use any type of multi-meter, digital or analog. Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. Hey John I just purchased a new pump for my pool. I bought a new pump thinking was something wrong with pump on off switch. So I need any kind of advice or help you can give me, before I have to call someone out. Check that hoses are clamped tight to fitting. When corrected, control will run blower for 5 s then automatically restart after 2 minutes. Conversely, and by the way, when pressure is much lower than normal, that indicates an obstruction before the filter, like clogged pump or skimmer baskets or an impeller clog. Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. likely not a fan or impeller problem, because at 3500 RPM (or less), it would wear down anything broken in just a few minutes. Thats either gears not engaged, or stuck or its a dead motor (timer motor). Is this a pump problem, priming problem (filter, pipes losing water somewhere)? And since it was running before (it shut off), its probably not rust.

Moving To Germany With Autistic Child, Tribute To A Wife Who Passed Away, Northampton County Judges, Articles H

hayward blue essence troubleshooting